Base reference coordinates
Set the reference coordinates of a base file in Rinexlab: why they matter in differential processing, the sources you can choose from, and why to declare their datum.
In differential processing, the coordinates of each base are held fixed. Any error in them goes straight into your result, so check them before you process.
Where the coordinates can come from
PPP result
The most reliable choice when you have no surveyed coordinates: run a static PPP of the base itself, two hours or more, then use its result
Differential result
A static differential result of the base file against other bases
Entered manually
Known coordinates of the point, for example a surveyed mark: latitude, longitude and ellipsoidal height
RINEX header
The position written by the receiver in the file header
File position (SPP)
The approximate position computed by Rinexlab on import. Accurate to a few metres only: not suited as a reference
Default on import: Rinexlab uses the position in the RINEX header when it lies within 1 km of its own approximate position, and the approximate position otherwise. A header position can be an approximate value: check it before processing.
Set the coordinates on the file page
Open the base file and go to the card Reference coordinates as base. It shows the current value, its source and its datum.
Use PPP result of date (or Use differential result of date): one click after a static job on the file.
Use the RINEX header: if the header has no coordinates, Rinexlab says so. Use a PPP of the base or enter the coordinates by hand.
Use the SPP position: the approximate position computed on import, only as a last resort.
Enter manually: type the latitude, longitude and ellipsoidal height, choose the Datum of these coordinates, then click Save reference.
The next differential jobs that use this base take the new coordinates.
Set the coordinates in the processing dialog
In Process differential, each base in the list shows where its reference comes from. Its Reference selector offers the file position, the RINEX header, the latest static PPP or differential results of that base, or a manual entry. Click Apply to set it.
A base without reference coordinates cannot be used: the dialog reports "A selected base has no reference coordinates".
Declare the datum
Declaring the datum of the coordinates lets Rinexlab express your differential results in another datum. Coordinates from a national network are usually in the national datum, for example RGF93 for the French RGP. Coordinates from an SPP or a PPP result are in ITRF2020.
The differential result follows the frame of the base coordinates. An output datum can be chosen only when every base has a declared datum.
Last updated: 28 October 2026